TY - JOUR
T1 - Verificación de niveles de atenuación de protectores auditivos tipo copa en trabajadores del sector hidrocarburos
AU - Upegui-Rincon, Sildrey
AU - Araque-Muñoz, Luis
AU - Lizarazo-Salcedo, Cesar
AU - Berrio-Garcia, Shyrle
AU - Guarguati-Ariza, Juliana
N1 - Publisher Copyright:
© 2019, Universidad Nacional de Colombia. All rights reserved.
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Objective To verify the attenuation levels of two types of earmuffs under real operating conditions. Materials and Methods A study with experimental design was carried out to obtain repeated measurements of the sound pressure levels inside and outside hearing protectors in a sample of workers of an oil and gas company working under normal process and exposure conditions. The results allowed determining differences between the attenuation levels established by the manufacturer, the adjusted attenuation levels under the NIOSH method, and the attenuation levels obtained experimentally. Results The attenuation values established by the manufacturers are lower than those ones obtained under actual use conditions in all cases evaluated. Likewise, the attenuation values of the hearing protectors, once adjusted under the NIOSH method, reached values much closer to those obtained experimentally. Conclusions The variability between theoretical attenuation values and experimental values allows concluding that the attenuation levels obtained under controlled laboratory conditions do not take into account certain characteristics that, based on their use, affect the efficiency of the hearing protection device. This study encourages the implementation of comprehensive hearing protection programs that consider variables such as hearing protection effectiveness, under real use conditions, by applying fit tests or other adjustment factors like the one suggested by NIOSH. This would ensure an adequate selection that aims at achieving an effective control of this risk factor.
AB - Objective To verify the attenuation levels of two types of earmuffs under real operating conditions. Materials and Methods A study with experimental design was carried out to obtain repeated measurements of the sound pressure levels inside and outside hearing protectors in a sample of workers of an oil and gas company working under normal process and exposure conditions. The results allowed determining differences between the attenuation levels established by the manufacturer, the adjusted attenuation levels under the NIOSH method, and the attenuation levels obtained experimentally. Results The attenuation values established by the manufacturers are lower than those ones obtained under actual use conditions in all cases evaluated. Likewise, the attenuation values of the hearing protectors, once adjusted under the NIOSH method, reached values much closer to those obtained experimentally. Conclusions The variability between theoretical attenuation values and experimental values allows concluding that the attenuation levels obtained under controlled laboratory conditions do not take into account certain characteristics that, based on their use, affect the efficiency of the hearing protection device. This study encourages the implementation of comprehensive hearing protection programs that consider variables such as hearing protection effectiveness, under real use conditions, by applying fit tests or other adjustment factors like the one suggested by NIOSH. This would ensure an adequate selection that aims at achieving an effective control of this risk factor.
KW - Ear protective devices
KW - Earmuffs
KW - Occupational exposure
KW - Occupational noise
UR - http://www.scopus.com/inward/record.url?scp=85081011762&partnerID=8YFLogxK
U2 - 10.15446/rsap.v21n2.70989
DO - 10.15446/rsap.v21n2.70989
M3 - Artículo
C2 - 33027329
AN - SCOPUS:85081011762
SN - 0124-0064
VL - 21
SP - 195
EP - 201
JO - Revista de Salud Publica
JF - Revista de Salud Publica
IS - 2
ER -