Transmisión de cargas entre forjados y puntales en un edificio de forjado reticular de casetón perdido utilizando clareado

I. Gasch, Y. A. Alvarado, P. A. Calderón, B. Torres

Producción: Contribución a una revistaArtículorevisión exhaustiva

10 Citas (Scopus)

Resumen

This paper presents the results of tests carried out during the construction of a building of flats with cast-in-place girderless hollow floor slab in Sabadell, Spain, using the shoring, clearing and striking (SCS) process. Loads on shores were recorded during the different construction stages of floor slabs 1 to 6. The two first floor slabs had geometry different than the rest. The experimental results were used to analyse load transmission between slabs and shores during the construction of the building with a SCS process. The experimental results were compared with those obtained applying simplified methods that consider the real stiffness of the shoring, obtaining that the method with a better fit was the New Simplified Procedure.

Título traducido de la contribuciónLoad transmission between slabs and shores in a building with cast-in-place girderless hollow floor slab using partial striking
Idioma originalEspañol
Páginas (desde-hasta)195-202
Número de páginas8
PublicaciónInformes de la Construccion
Volumen65
N.º530
DOI
EstadoPublicada - 2013

Palabras clave

  • Clearing
  • Construction process
  • Experimental study
  • Load transmission
  • New simplified procedure