Seismic performance of frames with passive energy dissipation steel slit plates

Título traducido de la contribución: Desempeño sísmico de un pórtico con disipadores de energía pasivos de placas ranuradas de acero

Juan Pimiento, Andrés Salas, Daniel Ruiz

Producción: Contribución a una revistaArtículorevisión exhaustiva

5 Citas (Scopus)

Resumen

This paper evaluates two types of hysteretic passive energy dissipation devices (steel slit plates). These devices are low-cost and easy to build and install. The seismic performance of three structural models were studied with shake table tests: a frame without energy dissipation device and two frames with two types of steel slit plates. The models were instrumented with accelerometers, strain gages and LVDTs, and were subjected to two types of earthquakes signals: a regional earthquake and a near-field ground motion. The results of laboratory tests suggest that the frame with steel slit plates have up to 90% less seismic drift than the frame without rehabilitation. This is because steel slit plates dissipated a large portion of the input energy supplied by earthquakes and the damage to the parent structure was minimized.

Título traducido de la contribuciónDesempeño sísmico de un pórtico con disipadores de energía pasivos de placas ranuradas de acero
Idioma originalInglés
Páginas (desde-hasta)283-298
Número de páginas16
PublicaciónRevista Ingenieria de Construccion
Volumen29
N.º3
DOI
EstadoPublicada - 01 dic. 2014

Huella

Profundice en los temas de investigación de 'Desempeño sísmico de un pórtico con disipadores de energía pasivos de placas ranuradas de acero'. En conjunto forman una huella única.

Citar esto