TY - JOUR
T1 - Reference values of upper extremity nerve conduction studies in a Colombian population
AU - Esteves, Enrique A.
AU - Guio, Sandra P.
AU - de los Reyes-Guevara, Carlos A.
AU - Cantor, Erika
AU - Habeych, Miguel E.
AU - Malagón, Adriana L.
N1 - Publisher Copyright:
© 2020
PY - 2020
Y1 - 2020
N2 - Objective: To establish appropriate reference values of upper extremity nerve conduction studies (NCS) at the Del Valle University Hospital, from Colombia. Methods: Two hundred and twenty-two (N = 222) healthy volunteers were recruited. Latencies, amplitudes and conduction velocities from the Median, Ulnar, and Radial nerves were performed following recommendations from Buschbacher and Prahlow. Then, according to the American Association of Neuromuscular and Electrodiagnostic Medicine (AANEM) task force for reference value establishment, analyses of variance were run where each electrophysiological parameter from every nerve tested was used as dependent variable, to define which characteristics have to be kept for the model. Percentiles 3 and 97 from each of the parameters were derived. Finally, a multivariate quantile regression analysis model was tested. Results: Sensory percentiles were 2.8–3.5 ms, 18.9–120.8 μV, and 40.0–50.0 m/s for the Median, 2.1–2.9 ms, 10.4–106.9 μV, and 41.0–58.0 m/s for the Ulnar, while 2.6–3.5 ms, 11.3–69.9 μV, and 39.0–54.0 m/s for the Radial nerve. The same parameters for motor function were 2.8–3.9 ms, 4.6–15.0 mV, and 49.0–68.0 m/s for the Median, while 2.3–3.5 ms, 3.9–11.5 mV and 51.0–70 m/s for the Ulnar nerve. Conclusions: Values of latency, amplitude, and conduction velocity of sensory and motor functions from upper extremity nerves among Colombians are similar to equal parameters, obtained by comparable studies of populations alike. Significance: This is the first study to establish reference values for upper extremity NCS carried out following the AANEM recommendations in a South American population.
AB - Objective: To establish appropriate reference values of upper extremity nerve conduction studies (NCS) at the Del Valle University Hospital, from Colombia. Methods: Two hundred and twenty-two (N = 222) healthy volunteers were recruited. Latencies, amplitudes and conduction velocities from the Median, Ulnar, and Radial nerves were performed following recommendations from Buschbacher and Prahlow. Then, according to the American Association of Neuromuscular and Electrodiagnostic Medicine (AANEM) task force for reference value establishment, analyses of variance were run where each electrophysiological parameter from every nerve tested was used as dependent variable, to define which characteristics have to be kept for the model. Percentiles 3 and 97 from each of the parameters were derived. Finally, a multivariate quantile regression analysis model was tested. Results: Sensory percentiles were 2.8–3.5 ms, 18.9–120.8 μV, and 40.0–50.0 m/s for the Median, 2.1–2.9 ms, 10.4–106.9 μV, and 41.0–58.0 m/s for the Ulnar, while 2.6–3.5 ms, 11.3–69.9 μV, and 39.0–54.0 m/s for the Radial nerve. The same parameters for motor function were 2.8–3.9 ms, 4.6–15.0 mV, and 49.0–68.0 m/s for the Median, while 2.3–3.5 ms, 3.9–11.5 mV and 51.0–70 m/s for the Ulnar nerve. Conclusions: Values of latency, amplitude, and conduction velocity of sensory and motor functions from upper extremity nerves among Colombians are similar to equal parameters, obtained by comparable studies of populations alike. Significance: This is the first study to establish reference values for upper extremity NCS carried out following the AANEM recommendations in a South American population.
KW - Colombia
KW - Median nerve
KW - Radial nerve
KW - Reference values
KW - Ulnar nerve
UR - http://www.scopus.com/inward/record.url?scp=85082706201&partnerID=8YFLogxK
U2 - 10.1016/j.cnp.2020.02.001
DO - 10.1016/j.cnp.2020.02.001
M3 - Article
AN - SCOPUS:85082706201
SN - 2467-981X
VL - 5
SP - 73
EP - 78
JO - Clinical Neurophysiology Practice
JF - Clinical Neurophysiology Practice
ER -