TY - GEN
T1 - Performance of photovoltaic modules after an accelerated thermal cycling degradation test
AU - Perez, Aramis
AU - Marín, Luis G.
AU - Fuentes, Fernando
AU - Mendoza, Patricio
AU - Jimenez, Guillermo
AU - Orchard, Marcos
N1 - Publisher Copyright:
© 2019 Prognostics and Health Management Society. All rights reserved.
PY - 2019/9/23
Y1 - 2019/9/23
N2 - Typically, datasheets of photovoltaic (PV) modules state that the guaranteed power production remains constant for a certain period of time and after this point, a linear reduction begins reaching an estimated 80% of the original rated power. Moreover, literature reports that the degradation of PV modules reaches less than 1% per year. In this regard, after 20 years of operation a typical PV module will deliver approximately 20% less energy than at the beginning of its life. In this article, the results of an accelerated thermal cycling degradation test are compared to its brand new conditions. These results demonstrate that although the performance among the PV modules is variable when new, after the cycling test the performance of the degraded PV modules is similar. In this case, the power reduction of the degraded module varies from 1.4% up o 7.6% when compared to the initial condition. Furthermore, an Electrochemical Impedance Spectroscopy (EIS) analysis demonstrates that at high frequencies the results are practically the same regardless if the panel is new or degraded, but at low frequencies the variation of the impedance is notorious.
AB - Typically, datasheets of photovoltaic (PV) modules state that the guaranteed power production remains constant for a certain period of time and after this point, a linear reduction begins reaching an estimated 80% of the original rated power. Moreover, literature reports that the degradation of PV modules reaches less than 1% per year. In this regard, after 20 years of operation a typical PV module will deliver approximately 20% less energy than at the beginning of its life. In this article, the results of an accelerated thermal cycling degradation test are compared to its brand new conditions. These results demonstrate that although the performance among the PV modules is variable when new, after the cycling test the performance of the degraded PV modules is similar. In this case, the power reduction of the degraded module varies from 1.4% up o 7.6% when compared to the initial condition. Furthermore, an Electrochemical Impedance Spectroscopy (EIS) analysis demonstrates that at high frequencies the results are practically the same regardless if the panel is new or degraded, but at low frequencies the variation of the impedance is notorious.
UR - http://www.scopus.com/inward/record.url?scp=85083695000&partnerID=8YFLogxK
U2 - 10.36001/phmconf.2019.v11i1.856
DO - 10.36001/phmconf.2019.v11i1.856
M3 - Conference contribution
AN - SCOPUS:85083695000
T3 - Proceedings of the Annual Conference of the Prognostics and Health Management Society, PHM
BT - Proceedings of the Annual Conference of the Prognostics and Health Management Society, PHM
A2 - Clements, N. Scott
A2 - Zhang, Bin
A2 - Saxena, Abhinav
PB - Prognostics and Health Management Society
T2 - 11th Annual Conference of the Prognostics and Health Management Society, PHM 2019
Y2 - 23 September 2019 through 26 September 2019
ER -