One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

L. Agulles-Pedrós, A. Abril

Producción: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

Resumen

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

Idioma originalInglés
Título de la publicación alojadaLatin American Symposium on Nuclear Physics and Applications, LASNPA 2015
EditoresFernando Cristancho
EditorialAmerican Institute of Physics Inc.
ISBN (versión digital)9780735414112
DOI
EstadoPublicada - 07 jul. 2016
Publicado de forma externa
Evento11th Latin American Symposium on Nuclear Physics and Applications, LASNPA 2015 - Medellin, Colombia
Duración: 30 nov. 201504 dic. 2015

Serie de la publicación

NombreAIP Conference Proceedings
Volumen1753
ISSN (versión impresa)0094-243X
ISSN (versión digital)1551-7616

Conferencia

Conferencia11th Latin American Symposium on Nuclear Physics and Applications, LASNPA 2015
País/TerritorioColombia
CiudadMedellin
Período30/11/1504/12/15

Huella

Profundice en los temas de investigación de 'One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector'. En conjunto forman una huella única.

Citar esto