TY - JOUR
T1 - Intraoperative Monitoring and Intra-abdominal Fluid Extravasation During Hip Arthroscopy
AU - Aguilera-Bohórquez, Bernardo
AU - Cantor, Erika
AU - Ramos-Cardozo, Orlando
AU - Pachón-Vásquez, Mauricio
N1 - Publisher Copyright:
© 2019 Arthroscopy Association of North America
PY - 2020/1
Y1 - 2020/1
N2 - Objective: To evaluate the relationship between the intraoperative monitoring factors with intra-abdominal fluid extravasation (IAFE) in patients who underwent hip arthroscopy. The secondary purpose was to describe the main intraoperative variables between cases with and without IAFE. Methods: We carried out a prospective observational study of 106 hip arthroscopies between June 2017 and June 2018. Within procedures, 54 cases with deep gluteal syndrome (DGS) were included. Ultrasonography was performed by a trained anesthesiologist before and after the surgery to identify the presence of fluid. The hepatorenal (Morison's pouch), splenorenal, retroaortic, suprapubic (longitudinal and transverse), and pleural spaces were examined. During the surgery, the blood pressure, heart rate, temperature, peak inspiratory pressure (PIP), pulmonary compliance, oxygen saturation, and end-tidal carbon dioxide were registered. Results: The incidence of IAFE was 31.1% (33/106; 95% confidence interval 23.0%-40.5%). IAFE in cases with isolated FAI was 15.9% (7/44) in comparison with 52.9% (9/17) of the cases with isolated DGS. Maximum values of PIP greater than 20 mm Hg were associated with fluid extravasation (odds ratio 3.22; 95% confidence interval 1.07-9.68). No statistically significant relationship was found in blood pressure, heart rate, temperature, oxygen saturation, end-tidal carbon dioxide, and pulmonary compliance between cases with and without IAFE. Conclusions: Asymptomatic IAFE, as measured by ultrasound, is a frequent event in patients who underwent hip arthroscopy, mainly in cases with DGS. PIP was found to be a useful intraoperative monitoring parameter for the early identification of IAFE in hip arthroscopy. Level of Evidence: Level II, observational prospective cohort study.
AB - Objective: To evaluate the relationship between the intraoperative monitoring factors with intra-abdominal fluid extravasation (IAFE) in patients who underwent hip arthroscopy. The secondary purpose was to describe the main intraoperative variables between cases with and without IAFE. Methods: We carried out a prospective observational study of 106 hip arthroscopies between June 2017 and June 2018. Within procedures, 54 cases with deep gluteal syndrome (DGS) were included. Ultrasonography was performed by a trained anesthesiologist before and after the surgery to identify the presence of fluid. The hepatorenal (Morison's pouch), splenorenal, retroaortic, suprapubic (longitudinal and transverse), and pleural spaces were examined. During the surgery, the blood pressure, heart rate, temperature, peak inspiratory pressure (PIP), pulmonary compliance, oxygen saturation, and end-tidal carbon dioxide were registered. Results: The incidence of IAFE was 31.1% (33/106; 95% confidence interval 23.0%-40.5%). IAFE in cases with isolated FAI was 15.9% (7/44) in comparison with 52.9% (9/17) of the cases with isolated DGS. Maximum values of PIP greater than 20 mm Hg were associated with fluid extravasation (odds ratio 3.22; 95% confidence interval 1.07-9.68). No statistically significant relationship was found in blood pressure, heart rate, temperature, oxygen saturation, end-tidal carbon dioxide, and pulmonary compliance between cases with and without IAFE. Conclusions: Asymptomatic IAFE, as measured by ultrasound, is a frequent event in patients who underwent hip arthroscopy, mainly in cases with DGS. PIP was found to be a useful intraoperative monitoring parameter for the early identification of IAFE in hip arthroscopy. Level of Evidence: Level II, observational prospective cohort study.
UR - http://www.scopus.com/inward/record.url?scp=85076247155&partnerID=8YFLogxK
U2 - 10.1016/j.arthro.2019.07.031
DO - 10.1016/j.arthro.2019.07.031
M3 - Article
C2 - 31864567
AN - SCOPUS:85076247155
SN - 0749-8063
VL - 36
SP - 139
EP - 147
JO - Arthroscopy - Journal of Arthroscopic and Related Surgery
JF - Arthroscopy - Journal of Arthroscopic and Related Surgery
IS - 1
ER -