TY - JOUR
T1 - Impact of sensor-augmented pump therapy with predictive low-glucose management on hypoglycemia and glycemic control in patients with type 1 diabetes mellitus
T2 - 1-year follow-up
AU - Gómez, Ana M.
AU - Henao, Diana C.
AU - Taboada, Lucía B.
AU - Leguizamón, Guillermo
AU - Rondón, Martín A.
AU - Muñoz, Oscar M.
AU - García-Jaramillo, Maira A.
AU - León Vargas, Fabián M.
N1 - Publisher Copyright:
© 2019
PY - 2019/7/1
Y1 - 2019/7/1
N2 - Aims: To describe real-life experience with sensor-augmented pump therapy with predictive low-glucose management (SAPT-PLGM), in terms of hypoglycemia and glycemic control after one year of follow-up in T1D patients with hypoglycemia as the main indication of therapy. Methods: Retrospective cohort study under real life conditions. Baseline and one-year follow-up variables of glycemic control, hypoglycemia and glycemic variability were compared. Results: Fifty patients were included, 31 on prior treatment with SAPT with low-glucose suspend (LGS) feature and 19 on multiple dose insulin injections (MDI). Mean HbA1c decreased in the MDI group (8.24%–7.08%; p = 0.0001). HbA1c change was not significant in the SAPT-LGS group. Area under the curve (AUC) below 70 mg/dl improved in both SAPT-LGS and MDI groups while AUC, %time and events below 54 mg/dl decreased in SAPT-LGS group. Glycemic variability improved in the MDI group. Less patients presented severe hypoglycemia with SAPT-PLGM in both groups, however the change was non-significant. Conclusions: Under real life conditions, SAPT-PLGM reduced metrics of hypoglycemia in patients previously treaded with MDI and SAPT-LGS without deteriorating glycemic control in SAPT-LGS patients, while improving it in patients treated with MDI.
AB - Aims: To describe real-life experience with sensor-augmented pump therapy with predictive low-glucose management (SAPT-PLGM), in terms of hypoglycemia and glycemic control after one year of follow-up in T1D patients with hypoglycemia as the main indication of therapy. Methods: Retrospective cohort study under real life conditions. Baseline and one-year follow-up variables of glycemic control, hypoglycemia and glycemic variability were compared. Results: Fifty patients were included, 31 on prior treatment with SAPT with low-glucose suspend (LGS) feature and 19 on multiple dose insulin injections (MDI). Mean HbA1c decreased in the MDI group (8.24%–7.08%; p = 0.0001). HbA1c change was not significant in the SAPT-LGS group. Area under the curve (AUC) below 70 mg/dl improved in both SAPT-LGS and MDI groups while AUC, %time and events below 54 mg/dl decreased in SAPT-LGS group. Glycemic variability improved in the MDI group. Less patients presented severe hypoglycemia with SAPT-PLGM in both groups, however the change was non-significant. Conclusions: Under real life conditions, SAPT-PLGM reduced metrics of hypoglycemia in patients previously treaded with MDI and SAPT-LGS without deteriorating glycemic control in SAPT-LGS patients, while improving it in patients treated with MDI.
KW - Diabetes mellitus
KW - Glycated hemoglobin A
KW - Hypoglycemia
KW - Insulin infusion systems
KW - Sensor-augmented pump therapy
KW - Type 1
UR - http://www.scopus.com/inward/record.url?scp=85068894227&partnerID=8YFLogxK
U2 - 10.1016/j.dsx.2019.07.024
DO - 10.1016/j.dsx.2019.07.024
M3 - Article
C2 - 31405686
AN - SCOPUS:85068894227
SN - 1871-4021
VL - 13
SP - 2625
EP - 2631
JO - Diabetes and Metabolic Syndrome: Clinical Research and Reviews
JF - Diabetes and Metabolic Syndrome: Clinical Research and Reviews
IS - 4
ER -