Resumen
This work presents the Hamming method generalized corrector for numerically resolving the differential equation of delayed neutron precursor concentration from the point kinetics equations for reactivity calculation, without using the nuclear power history or the Laplace transform. A study was carried out of several correctors with their respective modifiers with different time step calculations, to offer stability and greater precision. Better results are obtained for some correctors than with other existing methods. Reactivity can be calculated with precision of the order h5, where h is the time step.
Idioma original | Inglés |
---|---|
Páginas (desde-hasta) | 219-225 |
Número de páginas | 7 |
Publicación | Kerntechnik |
Volumen | 79 |
N.º | 3 |
DOI | |