Explantador de Cabrera: un nuevo dispositivo para explantar endoprótesis aórticas después de reparo endovascular de aneurisma de aorta, un estudio experimental ex vivo

Luis Felipe Cabrera-Vargas, Iván Lozada-Martínez, Nicolás Forero-Ramírez, Hernando Thorne-Vélez

Producción: Contribución a una revistaArtículorevisión exhaustiva

Resumen

Introduction. Complications after endovascular aneurysm repair (EVAR) can be resolved with endovascular techniques; however, when indicated, stent explantation is a complex procedure, which is associated with vascular or visceral injuries, with high morbidity and mortality in patients, with advanced age and multiple comorbidities, and therefore high surgical risk. There are no devices produced by the industry to explant aortic endoprostheses, so the objective of this work was to develop a device for the explantation of aortic endoprostheses. Methods. An experimental study was carried out, in the preclinical phase, to develop a device for the explantation of aortic endoprostheses, with tests in 3D models and in a cadaveric porcine animal model. Results. It is feasible to develop an experimental model of a new device for explanting aortic endoprostheses, called Cabrera explanter, and verify its operation in a cadaveric animal model. The use of the Cabrera explanter limited damage to the aortic wall by the endoprosthesis by 100% at the time of explantation in an ex vivo experimental model. Conclusions. Using a septum syringe, the Cabrera explanter is superior to the standard stent explantation technique by limiting injury to the aortic wall, collapsing and releasing the adrenal fixation hooks in a controlled and safe manner into the aortic lumen, and subsequently, extract it quickly and effectively, preserving the greatest amount of healthy aorta for the subsequent aorto-iliac reconstruction.

Título traducido de la contribuciónCabrera explanter: a new device to explant aortic stents after endovascular aortic aneurysm repair, an ex vivo experimental study
Idioma originalEspañol
Páginas (desde-hasta)580-589
Número de páginas10
PublicaciónRevista Colombiana de Cirugia
Volumen39
N.º4
DOI
EstadoPublicada - 05 jul. 2024
Publicado de forma externa

Palabras clave

  • abdominal aorta
  • abdominal aortic aneurysm
  • device removal
  • endovascular aneurysm repair
  • endovascular procedures
  • prostheses and implants

Huella

Profundice en los temas de investigación de 'Explantador de Cabrera: un nuevo dispositivo para explantar endoprótesis aórticas después de reparo endovascular de aneurisma de aorta, un estudio experimental ex vivo'. En conjunto forman una huella única.

Citar esto