TY - JOUR
T1 - Continuous glucose monitoring in insulin-Treated patients in non-ICU settings
AU - Gomez, Ana Maria
AU - Umpierrez, Guillermo E.
N1 - Publisher Copyright:
© 2014 Diabetes Technology Society.
PY - 2014/1/1
Y1 - 2014/1/1
N2 - Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-Time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-Time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-Treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-Time CGM in the management of dysglycemia in the hospital setting.
AB - Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-Time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-Time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-Treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-Time CGM in the management of dysglycemia in the hospital setting.
KW - Continuous glucose monitoring
KW - Glucose monitoring
KW - Inpatient hyperglycemia
KW - Point of care testing
UR - http://www.scopus.com/inward/record.url?scp=84925036253&partnerID=8YFLogxK
U2 - 10.1177/1932296814546025
DO - 10.1177/1932296814546025
M3 - Article
C2 - 25125454
AN - SCOPUS:84925036253
SN - 1932-2968
VL - 8
SP - 930
EP - 936
JO - Journal of Diabetes Science and Technology
JF - Journal of Diabetes Science and Technology
IS - 5
ER -