TY - JOUR
T1 - Conductimetry
T2 - A rapid alternative technique for chlorides determination in cheese
AU - Aguirre-Londoño, Jessica
AU - Aristizabal-Ferreira, Víctor Alexander
AU - Castro-Narváez, Sandra Patricia
AU - Ramírez-Navas, Juan Sebastián
N1 - Publisher Copyright:
© 2019, Pontificia Universidad Javeriana.
PY - 2019
Y1 - 2019
N2 - The correlation of two instrumental techniques for chlorides determination in Colombian cheese, Queso Molido Nariñense (a type of white cheese), was analyzed. Potentiometry of chloride precipitation is the standard technique to determined salt in cheese. Conductimetry is an alternative technique. Samples of Queso Molido Nariñense were made. In the processed cheeses the salt concentration (NaCl: 0.5 %, 0.8 %, 1.0 %, 2.0 %, 3.0% and 6.0 %) was varied. Chlorides were determined by titration with silver nitrate in the potentiometric technique. In the conductimetric technique, each sample was analyzed by direct measuring its conductivity at room temperature. It was found that there is an adequate correlation between potentiometry and conductimetry. A maximum concentration of 2% NaCl in cheese is equivalent to 2.9 S/cm for conductivity readings. Additionally, it was verified that the conductimetry constitutes an analytically reliable technique for the determination of chlorides in cheese, it is friendlier to the environment, cheaper and faster.
AB - The correlation of two instrumental techniques for chlorides determination in Colombian cheese, Queso Molido Nariñense (a type of white cheese), was analyzed. Potentiometry of chloride precipitation is the standard technique to determined salt in cheese. Conductimetry is an alternative technique. Samples of Queso Molido Nariñense were made. In the processed cheeses the salt concentration (NaCl: 0.5 %, 0.8 %, 1.0 %, 2.0 %, 3.0% and 6.0 %) was varied. Chlorides were determined by titration with silver nitrate in the potentiometric technique. In the conductimetric technique, each sample was analyzed by direct measuring its conductivity at room temperature. It was found that there is an adequate correlation between potentiometry and conductimetry. A maximum concentration of 2% NaCl in cheese is equivalent to 2.9 S/cm for conductivity readings. Additionally, it was verified that the conductimetry constitutes an analytically reliable technique for the determination of chlorides in cheese, it is friendlier to the environment, cheaper and faster.
KW - Colombian cheese
KW - Conductimetry
KW - Potentiometry
KW - Sodium chloride
KW - White cheese
UR - http://www.scopus.com/inward/record.url?scp=85067679104&partnerID=8YFLogxK
U2 - 10.11144/Javeriana.SC24-2.cara
DO - 10.11144/Javeriana.SC24-2.cara
M3 - Article
AN - SCOPUS:85067679104
SN - 0122-7483
VL - 24
SP - 307
EP - 322
JO - Universitas Scientiarum
JF - Universitas Scientiarum
IS - 2
ER -