@inproceedings{e4c35b12ad294f86b0e45db7e4e572af,
title = "Comparison of robust control laws for a DC/DC ladder multilevel converter",
abstract = "In this article different control methods for a ladder multilevel converter (two cells) are evaluated. An analysis of the classical average model allows to chose a set of operation points and construct an uncertain model. Moreover, the necessary disturbance variables and performance masks are defined. All this information is used to design an H ∞ mixed sensitivity and (DK) robust control laws for the Ladder multilevel converter. The performance and robustness as voltage regulators of the different controllers are compared through simulation with a classical PI control law.",
keywords = "(DK) control, H control, Ladder multilevel converter, performance masks, uncertainty",
author = "Andres Lopez and Diego Patino and Rafael Diez and Gabriel Perilla",
year = "2012",
doi = "10.1109/ICIT.2012.6210009",
language = "English",
isbn = "9781467303422",
series = "2012 IEEE International Conference on Industrial Technology, ICIT 2012, Proceedings",
pages = "632--637",
booktitle = "2012 IEEE International Conference on Industrial Technology, ICIT 2012, Proceedings",
note = "2012 IEEE International Conference on Industrial Technology, ICIT 2012 ; Conference date: 19-03-2012 Through 21-03-2012",
}