TY - JOUR
T1 - Clinical factors associated with high glycemic variability defined by coefficient of variation in patients with type 2 diabetes
AU - Gómez, A. M.
AU - Henao-Carillo, D. C.
AU - Taboada, L.
AU - Fuentes, O.
AU - Lucero, O.
AU - Sanko, A.
AU - Robledo, M. A.
AU - Muñoz, O.
AU - Rondón, M.
AU - García-Jaramillo, M.
AU - León-Vargas, F.
N1 - Publisher Copyright:
© 2021 Gómez et al.
PY - 2021
Y1 - 2021
N2 - Background: High glycemic Variability (HGV) has become a stronger predictor of hypoglycemia. However, clinical factors associate with HGV still are unknown. Objective: To determine clinical variables that were associated with a coefficient of variation (CV) above 36% evaluated by continuous glucose monitoring (CGM) in a group of patients with diabetes mellitus. Methods: A cohort of patients with type 2 diabetes (T2D) was evaluated. Demographic variables, HbA1c, glomerular filtration rate (GFR) and treatment regimen were assessed. A bivariate analysis was performed, to evaluate the association between the outcome variable (CV> 36%) and each of the independent variables. A multivariate model was constructed to evaluate associations after controlling for confounding variables. Results: CGM data from 274 patients were analyzed. CV> 36% was present in 56 patients (20.4%). In the bivariate analysis, demographic and clinical variables were included, such as time since diagnosis, hypoglycemia history, A1c, GFR and treatment established. In the multivariate analysis, GFR <45 mL/min (OR 2.81; CI 1.27,6.23; p:0.01), A1c > 9% (OR 2.81; CI 1.05,7.51; p:0.04) and hypoglycemia history (OR 2.09; CI 1.02,4.32; p:0.04) were associated with HGV. Treatment with iDPP4 (OR 0.39; CI 0.19,0.82; p:0.01) and AGLP1 (OR 0.08; CI 0.01,0.68; p:0.02) was inversely associated with GV. Conclusion: Clinical variables such as GFR <45 mL/min, HbA1C>9% and a history of hypoglycemia are associated with a high GV. Our data suggest that the use of technology and treatments able to reduce glycemic variability could be useful in this population to reduce the risk of hypoglycemia and to improve glycemic control.
AB - Background: High glycemic Variability (HGV) has become a stronger predictor of hypoglycemia. However, clinical factors associate with HGV still are unknown. Objective: To determine clinical variables that were associated with a coefficient of variation (CV) above 36% evaluated by continuous glucose monitoring (CGM) in a group of patients with diabetes mellitus. Methods: A cohort of patients with type 2 diabetes (T2D) was evaluated. Demographic variables, HbA1c, glomerular filtration rate (GFR) and treatment regimen were assessed. A bivariate analysis was performed, to evaluate the association between the outcome variable (CV> 36%) and each of the independent variables. A multivariate model was constructed to evaluate associations after controlling for confounding variables. Results: CGM data from 274 patients were analyzed. CV> 36% was present in 56 patients (20.4%). In the bivariate analysis, demographic and clinical variables were included, such as time since diagnosis, hypoglycemia history, A1c, GFR and treatment established. In the multivariate analysis, GFR <45 mL/min (OR 2.81; CI 1.27,6.23; p:0.01), A1c > 9% (OR 2.81; CI 1.05,7.51; p:0.04) and hypoglycemia history (OR 2.09; CI 1.02,4.32; p:0.04) were associated with HGV. Treatment with iDPP4 (OR 0.39; CI 0.19,0.82; p:0.01) and AGLP1 (OR 0.08; CI 0.01,0.68; p:0.02) was inversely associated with GV. Conclusion: Clinical variables such as GFR <45 mL/min, HbA1C>9% and a history of hypoglycemia are associated with a high GV. Our data suggest that the use of technology and treatments able to reduce glycemic variability could be useful in this population to reduce the risk of hypoglycemia and to improve glycemic control.
KW - Continuous glucose monitoring
KW - Diabetes mellitus
KW - Glycemic variability
KW - Variation coefficient
UR - http://www.scopus.com/inward/record.url?scp=85104096147&partnerID=8YFLogxK
U2 - 10.2147/MDER.S288526
DO - 10.2147/MDER.S288526
M3 - Article
AN - SCOPUS:85104096147
SN - 1179-1470
VL - 14
SP - 97
EP - 103
JO - Medical Devices: Evidence and Research
JF - Medical Devices: Evidence and Research
ER -