TY - JOUR
T1 - Automatic seizure detection based on imaged-EEG signals through fully convolutional networks
AU - Gómez, Catalina
AU - Arbeláez, Pablo
AU - Navarrete, Miguel
AU - Alvarado-Rojas, Catalina
AU - Le Van Quyen, Michel
AU - Valderrama, Mario
N1 - Publisher Copyright:
© 2020, The Author(s).
PY - 2020/12
Y1 - 2020/12
N2 - Seizure detection is a routine process in epilepsy units requiring manual intervention of well-trained specialists. This process could be extensive, inefficient and time-consuming, especially for long term recordings. We proposed an automatic method to detect epileptic seizures using an imaged-EEG representation of brain signals. To accomplish this, we analyzed EEG signals from two different datasets: the CHB-MIT Scalp EEG database and the EPILEPSIAE project that includes scalp and intracranial recordings. We used fully convolutional neural networks to automatically detect seizures. For our best model, we reached average accuracy and specificity values of 99.3% and 99.6%, respectively, for the CHB-MIT dataset, and corresponding values of 98.0% and 98.3% for the EPILEPSIAE patients. For these patients, the inclusion of intracranial electrodes together with scalp ones increased the average accuracy and specificity values to 99.6% and 58.3%, respectively. Regarding the other metrics, our best model reached average precision of 62.7%, recall of 58.3%, F-measure of 59.0% and AP of 54.5% on the CHB-MIT recordings, and comparatively lowers performances for the EPILEPSIAE dataset. For both databases, the number of false alarms per hour reached values less than 0.5/h for 92% of the CHB-MIT patients and less than 1.0/h for 80% of the EPILEPSIAE patients. Compared to recent studies, our lightweight approach does not need any estimation of pre-selected features and demonstrates high performances with promising possibilities for the introduction of such automatic methods in the clinical practice.
AB - Seizure detection is a routine process in epilepsy units requiring manual intervention of well-trained specialists. This process could be extensive, inefficient and time-consuming, especially for long term recordings. We proposed an automatic method to detect epileptic seizures using an imaged-EEG representation of brain signals. To accomplish this, we analyzed EEG signals from two different datasets: the CHB-MIT Scalp EEG database and the EPILEPSIAE project that includes scalp and intracranial recordings. We used fully convolutional neural networks to automatically detect seizures. For our best model, we reached average accuracy and specificity values of 99.3% and 99.6%, respectively, for the CHB-MIT dataset, and corresponding values of 98.0% and 98.3% for the EPILEPSIAE patients. For these patients, the inclusion of intracranial electrodes together with scalp ones increased the average accuracy and specificity values to 99.6% and 58.3%, respectively. Regarding the other metrics, our best model reached average precision of 62.7%, recall of 58.3%, F-measure of 59.0% and AP of 54.5% on the CHB-MIT recordings, and comparatively lowers performances for the EPILEPSIAE dataset. For both databases, the number of false alarms per hour reached values less than 0.5/h for 92% of the CHB-MIT patients and less than 1.0/h for 80% of the EPILEPSIAE patients. Compared to recent studies, our lightweight approach does not need any estimation of pre-selected features and demonstrates high performances with promising possibilities for the introduction of such automatic methods in the clinical practice.
UR - http://www.scopus.com/inward/record.url?scp=85097510494&partnerID=8YFLogxK
U2 - 10.1038/s41598-020-78784-3
DO - 10.1038/s41598-020-78784-3
M3 - Article
C2 - 33311533
AN - SCOPUS:85097510494
SN - 2045-2322
VL - 10
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 21833
ER -