Transmisión de cargas entre forjados y puntales en un edificio de forjado reticular de casetón perdido utilizando clareado

Translated title of the contribution: Load transmission between slabs and shores in a building with cast-in-place girderless hollow floor slab using partial striking

I. Gasch, Y. A. Alvarado, P. A. Calderón, B. Torres

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

This paper presents the results of tests carried out during the construction of a building of flats with cast-in-place girderless hollow floor slab in Sabadell, Spain, using the shoring, clearing and striking (SCS) process. Loads on shores were recorded during the different construction stages of floor slabs 1 to 6. The two first floor slabs had geometry different than the rest. The experimental results were used to analyse load transmission between slabs and shores during the construction of the building with a SCS process. The experimental results were compared with those obtained applying simplified methods that consider the real stiffness of the shoring, obtaining that the method with a better fit was the New Simplified Procedure.

Translated title of the contributionLoad transmission between slabs and shores in a building with cast-in-place girderless hollow floor slab using partial striking
Original languageSpanish
Pages (from-to)195-202
Number of pages8
JournalInformes de la Construccion
Volume65
Issue number530
DOIs
StatePublished - 2013

Fingerprint

Dive into the research topics of 'Load transmission between slabs and shores in a building with cast-in-place girderless hollow floor slab using partial striking'. Together they form a unique fingerprint.