Skip to main navigation Skip to search Skip to main content

Influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files

  • Álvaro Zubizarreta-Macho
  • , Jesús Mena Álvarez
  • , Alberto Albaladejo Martínez
  • , Juan José Segura-Egea
  • , Javier Caviedes Brucheli
  • , Rubén Agustín-Panadero
  • , Roberto López Píriz
  • , Óscar Alonso-Ezpeleta

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Purpose: To analyze the influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files. Material and Methods: Sixty PlexV 25.06 endodontic rotary files were selected and distributed into three groups: 30 movements/min (n = 20), 60 movements/min (n = 20), and 120 movements/min (n = 20). A dynamic cyclic fatigue device was designed using Computer Aided Design/ Computer Aided Engineering (CAD/CAE) technology and manufactured by 3D impressions to simulate the pecking motion performed by an operator. Failures of the endodontic rotary files were detected by a Light-Emitting Diode (LED)/Light-Dependent Resistor (LDR) system controlled by an Arduino-Driver complex and management software. Endodontic rotary files were tested on an artificial root canal manufactured by wire electrical discharge machining (EDM), with similar dimensions to those of the instrument under examination. Endodontic rotary files were used following the manufacturer’s recommendations. The results were analyzed by ANOVA and Weibull statistics. Results: All pairwise comparisons revealed statistically significant differences in all three variables, except for the difference in the number of cycles between the groups with 60 and 120 movements/min (p = 0.298). The scale distribution parameter of Weibull statistics showed statistically significant differences in all three variables, except for the differences in the number of cycles between groups with 30 and 60 movements/min (p = 0.0722). No statistically significant differences in the three variables were observed for the shape distribution parameter. Conclusion: A low frequency of pecking motion is recommended to reduce the risk of failure of endodontic rotary files associated with cyclic fatigue.

Original languageEnglish
Article number45
JournalJournal of Clinical Medicine
Volume9
Issue number1
DOIs
StatePublished - Jan 2020

Keywords

  • Cyclic fatigue
  • Endodontic rotary files
  • Endodontics
  • NiTi rotary files
  • Pecking motion

Fingerprint

Dive into the research topics of 'Influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files'. Together they form a unique fingerprint.

Cite this