Skip to main navigation Skip to search Skip to main content

Ineffective esophageal motility and bolus clearance. A study with combined high-resolution manometry and impedance in asymptomatic controls and patients

  • Frank Zerbib
  • , Ingrid Marin
  • , Daniel Cisternas
  • , Luiz Abrahao
  • , Albis Hani
  • , Ana M. Leguizamo
  • , José M. Remes-Troche
  • , Julio Perez de la Serna
  • , Antonio Ruiz de Leon
  • , Jordi Serra

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

Background: The definition and relevance of ineffective esophageal motility (IEM) remains debated. Our aim was to determine motility patterns and symptoms associated with IEM defined as impaired bolus clearance. Methods: To define altered bolus clearance, normal range of swallows with complete bolus transit (CBT) on high-resolution impedance manometry (HRIM) was determined in 44 asymptomatic controls. The results were then applied to a cohort of 81 patients with esophageal symptoms to determine the motility patterns which best predicted altered bolus clearance. Subsequently, in a cohort of 281 consecutive patients the identified motility patterns were compared with patients’ customary symptoms. Key Results: In asymptomatic controls, the normal range of swallows with CBT was 50%-100%. In patients, altered bolus transit (<50% CBT) was only associated with 30% or more failed contractions (P <.001). Neither weak peristalsis nor absence of contraction reserve (CR) was associated with altered bolus clearance. The patterns which best predicted altered bolus clearance were failed contractions ≥30% (specificity 88.2% and sensitivity of 84.6%), and ≥70% ineffective (failed + weak) contractions (sensitivity 84.6% and specificity 80.9%). No motility pattern was correlated to symptom scores. Conclusions and Inferences: Based on bolus clearance assessed by HRIM, ≥30% failed contractions and ≥70% ineffective contractions have the best sensitivity and specificity to predict altered bolus clearance. Weak contractions and absence of CR are not relevant with respect to bolus clearance.

Original languageEnglish
Article numbere13876
JournalNeurogastroenterology and Motility
Volume32
Issue number9
DOIs
StatePublished - 01 Sep 2020
Externally publishedYes

Keywords

  • esophageal bolus clearance
  • esophageal motility
  • high-resolution esophageal manometry
  • high-resolution impedance manometry

Fingerprint

Dive into the research topics of 'Ineffective esophageal motility and bolus clearance. A study with combined high-resolution manometry and impedance in asymptomatic controls and patients'. Together they form a unique fingerprint.

Cite this