Skip to main navigation Skip to search Skip to main content

Factores asociados con el control glucémico óptimo en pacientes tratados con bomba de insulina y monitorización continua de glucosa en tiempo real

Translated title of the contribution: Factors associated with optimal glycemic control in patients with insulin pump therapy and continuous glucose monitoring in real time
  • Hospital Universitario San Ignacio

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Objective When used with continuous glucose monitoring (CGM) and bolus estimation algorithms, many patients on insulin pump therapy achieve near-euglycemia. We evaluated the usage patterns of integrated pump/CGM technology that are associated with A1C levels < 7%. Methods Data from 217 patients (age > 11 years, 53.5% male, 91.7% with type 1 diabetes, all with > 3 months pump experience) receiving care at a teaching hospital in Bogotá, Colombia, were analyzed. Data included insulin delivery, A1C levels, severe hypoglycemic events, use of CGM, completion of diabetes education courses, and the frequency of blood glucose checks. All patients received training on the use of the pump, and most (73.7%) received additional training on carbohydrate counting, basal rate adjustments, and use of CGM data. Results Initiation of pump therapy was associated with decreases in A1C, insulin use, and severe hypoglycemic events (all P <.001). Pump and CGM-specific behaviors associated with lower A1C included the use of a dose estimation algorithm for > 80% of bolus doses and use of CGM sensors > 80% of the time (both P <.005). Lower A1C was also associated with the completion of additional training, age > 18, use of the Paradigm 722 pump with an integrated CGM device, use of CGM-based alarms, A1c >7% before pump therapy, and more frequent blood glucose checks (all P <.05). Many (45.6%) patients reached A1c ≤ 7% with pump therapy. Conclusions Patient education, with an A1c below 7% before sensor-augmented pump therapy, when combined with consistent use of CGM sensors and bolus estimation algorithms, leads to favorable reductions in A1C beyond those achieved with pump therapy alone.

Translated title of the contributionFactors associated with optimal glycemic control in patients with insulin pump therapy and continuous glucose monitoring in real time
Original languageSpanish
Pages (from-to)74-80
Number of pages7
JournalAvances en Diabetologia
Volume29
Issue number3
DOIs
StatePublished - May 2013
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Factors associated with optimal glycemic control in patients with insulin pump therapy and continuous glucose monitoring in real time'. Together they form a unique fingerprint.

Cite this