EXPERIENCIAS Y RESULTADOS DE LA OPERACIÓN Y MODELACIÓN DE LODOS ACTIVADOS PARA EL TRATAMIENTO DE AGUAS RESIDUALES DOMESTICAS EN BOGOTÁ

Research output: Contribution to conferencePaperpeer-review

Abstract

Pilot tests were carried out in a activated sludge plant, a high variability in the wastewater quality and non biodegradable soluble COD fractions (Fus =0.23). above the typical values (Fus =0.1). were found. Periodic testing of oxygen transfer efficiency in the aerobic reactor (process water) showed the negative influence of diffusers fouling in the aeration system performance (KLa in th range from 0.52 to 0.35). Using BioWin a model was calibrated and validate. The outcome of several simulations with selectors (anoxic and anaerobic) was evaluated regarding their influence on nutrient removal, oxygen demand and sludge production.
Original languageUndefined/Unknown
Pages1-9
Number of pages9
DOIs
StatePublished - Nov 2014
EventXXXIV Congreso interamericano de Ingeniería Sanitaria y Ambiental - Monterrey, Mexico
Duration: 02 Nov 201406 Nov 2014
Conference number: 34

Conference

ConferenceXXXIV Congreso interamericano de Ingeniería Sanitaria y Ambiental
Abbreviated titleAIDIS 2013
Country/TerritoryMexico
CityMonterrey
Period02/11/1406/11/14