Comparison of robust control laws for a DC/DC ladder multilevel converter

Andres Lopez, Diego Patino, Rafael Diez, Gabriel Perilla

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

5 Scopus citations

Abstract

In this article different control methods for a ladder multilevel converter (two cells) are evaluated. An analysis of the classical average model allows to chose a set of operation points and construct an uncertain model. Moreover, the necessary disturbance variables and performance masks are defined. All this information is used to design an H mixed sensitivity and (DK) robust control laws for the Ladder multilevel converter. The performance and robustness as voltage regulators of the different controllers are compared through simulation with a classical PI control law.

Original languageEnglish
Title of host publication2012 IEEE International Conference on Industrial Technology, ICIT 2012, Proceedings
Pages632-637
Number of pages6
DOIs
StatePublished - 2012
Event2012 IEEE International Conference on Industrial Technology, ICIT 2012 - Athens, Greece
Duration: 19 Mar 201221 Mar 2012

Publication series

Name2012 IEEE International Conference on Industrial Technology, ICIT 2012, Proceedings

Conference

Conference2012 IEEE International Conference on Industrial Technology, ICIT 2012
Country/TerritoryGreece
CityAthens
Period19/03/1221/03/12

Keywords

  • (DK) control
  • H control
  • Ladder multilevel converter
  • performance masks
  • uncertainty

Fingerprint