Skip to main navigation Skip to search Skip to main content

Active Osseointegrated Steady-State Implant System: Surgical and Clinical Performance

  • Leornardo Ordoñez-Ordoñez
  • , José Agustin Caraballo
  • , k. Jorge Guillermo Cabrera Ortiz
  • , Francisco Gonzalez Eslait
  • , Rafael Jaramillo Saffon
  • , José Gabriel Lora
  • , Santiago Hernandez
  • , Jose Guzman
  • , Luz Adriana Rincon
  • , Byanka Cagnacci Buzo
  • Universidad Militar Nueva Granada
  • Hospital de Caldas SES
  • Clínica Los Nogales
  • Hospital Universitario Mayor Méderi
  • Hospital San Rafael
  • Universidad Javeriana
  • Clínica Imbanaco - Quiron Salud
  • WSP Colombia
  • Cochlear LATAM
  • Universidad del Valle
  • Santa Casa de Sao Paulo School of Medical Science - Hearing and Speech Science Program
  • Instituto Para Niños Ciegos y Sordos Del Valle Del Cauca

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Purpose: We aimed to investigate the surgical outcomes and clinical performance of an active osseointegration implant system that uses piezoelectric technology. Methods: This national, multicenter, prospective, repeated measures study was approved by the Ethics Committee (opinion no. CEISH 0559-2019). The sample included patients with conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided deafness (SSD) who were eligible for osseointegrated implant surgery. Surgical parameters were assessed, along with functional and effective gain (FG and EG) and self-perception of benefits, which were evaluated between 3 and 6 months after activation. Participants also completed the Client Oriented Scale of Improvement (COSI) questionnaire to subjectively report expected and perceived benefits. Results: A total of 580 participants aged 5 to 73 years were included in the study between June 2020 and April 2023. Most participants were diagnosed with CHL (58.8%), followed by MHL (28.8%) and SSD. 11.4% of the surgeries involved conversion of other devices to the piezoelectric system. The mean surgery duration was 54 min, and the mean skin thickness was 5.6 mm. Soft tissue reduction was required for 4% of the participants, while 21.2% required bone polishing. The mean PTA (pure tone average) FG was 38.6 dB for participants with CHL, 44.4 dB for those with MHL, and 66.1 dB for those with SSD. Conclusion: These results confirmed the clinical safety, performance, and benefits of an innovative active transcutaneous bone conduction implant with a piezoelectric transducer design for patients with CHL, MHL, or SSD.

Original languageEnglish
Pages (from-to)e109-e116
JournalOtology and Neurotology
Volume46
Issue number4
DOIs
StatePublished - 01 Apr 2025

Keywords

  • Active transcutaneous bone conduction implant—Conductive hearing loss—Mixed hearing loss—Piezoelectric transductor—Single-sided deafness

Fingerprint

Dive into the research topics of 'Active Osseointegrated Steady-State Implant System: Surgical and Clinical Performance'. Together they form a unique fingerprint.

Cite this